Fluke 59 Max / 59 Max+ Infrared Thermometer
Technical Data
With 65 years of expertise as the leader in the test tools industry, Fluke has built the 59 MAX and 59 MAX+ IR thermometers with the precision you need to do your job accurately and within your budget. Designed to withstand a 1 meter drop, you can count on these lightweight, compact IR thermometers to work when you need them.
Specifications
- Temperature range 59 Max : -30 °C to 350 °C (-22 °Fto 662 °F)
- Temperature range 59 Max+ : -30 °C to 500 °C (-22 °Fto 932 °F)
Accuracy (Calibration geometry with ambient temperature 23 °C ±2 °C) 59 Max :
- ≥ 0 °C : ± 2.0 °C or ± 2.0 % of reading, whichever is greater
- ≥ -10 °C to <0 °C : ± 2.0 °C
- < -10 °C : ± 3.0 °C
- ≥ 32 °F : ± 4.0 °F or ± 2.0 % of reading, whichever is greater
- ≥ 14 °Fto <32 °F : ± 4.0 °F
- < 14 °F : ± 6.0 °F
Accuracy (Calibration geometry with ambient temperature 23 °C ±2 °C) 59 Max+ :
- ≥ 0 °C : ± 1.5 °C or ± 1.5 % of reading, whichever is greater
- ≥ -10 °C to <0 °C : ± 2.0 °C
- < -10 °C : ± 3.0 °C
- ≥ 32 °F : ± 3.0 °F or ± 1.5 % of reading, whichever is greater
- <14 °F : ± 6.0 °F
Response rime (95 %)
- 59 Max : <500 ms (95 % of reading)
- 59 Max+ : < 500 ms (95 % of reading)
Spectral response
Distance to spot ratio
- 59 Max : 8:1 (calculated at 90 % energy)
- 59 Max+ : 10:1 (calculated at 90 % energy)
Display resolution
Repeatability (% of reading)
- 59 Max : ±1.0 % of reading or ±1.0 °C (±2.0 °F), whichever is greater
- 59 Max+ : ±0.8 % of reading or ±1.0 °C (±2.0 °F), whichever is greater
General specifications
- Power : 1 AA IEC LR06 Battery
- Batter life : 12 hours with laser and backlight on
- Weight : 220 g (7.76 oz)
- Size : (156x80x50)mm(6.14x3.15x2)inches
- Operating temperature : 0 °C to 50 °C (32 °F to 122 °F)
- Storage temperature : -20 °C to +60 °C (-4 °F to 140 °F), (without battery)
- Operating humidity : 10 % to 90 % RH non-condensing @ 30 °C (86 °F)
- Operating altitude : 2000 meters above mean sea level
- Storage altitude : 12,000 meters above mean sea level
- Drop test : 1m
Safety specifications
- Ingress protection rating : IP40 per IEC 60529
- Vibration and shock : IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
- Compliance : EN/IEC 61010-1
- Laser safety : FDA and EN 60825-1 Class II
- Electromagnetic compatibility : 61326-1 EN 61326-2
Ordering information
- Fluke 59 MAX Infrared Thermometer | Fluke 59 MAX+ Infrared Thermometer
Included:
- Thermometer, One (1) AA battery, registration card and user instructions.